Wilo-Stratos Giga Vertical Single-Stage Low-Pressure High Flow Heating Circulation Pump

Product Details
Customization: Available
Max.Head: 80m
Max.Capacity: 450m³/H
Gold Member Since 2025

Suppliers with verified business licenses

Registered Capital
10000000 RMB
Plant Area
1001~2000 square meters
  • Wilo-Stratos Giga Vertical Single-Stage Low-Pressure High Flow Heating Circulation Pump
  • Wilo-Stratos Giga Vertical Single-Stage Low-Pressure High Flow Heating Circulation Pump
  • Wilo-Stratos Giga Vertical Single-Stage Low-Pressure High Flow Heating Circulation Pump
  • Wilo-Stratos Giga Vertical Single-Stage Low-Pressure High Flow Heating Circulation Pump
  • Wilo-Stratos Giga Vertical Single-Stage Low-Pressure High Flow Heating Circulation Pump
  • Wilo-Stratos Giga Vertical Single-Stage Low-Pressure High Flow Heating Circulation Pump
Find Similar Products

Basic Info.

Model NO.
Wilo-Stratos GIGA
Driving Type
Motor
Impeller Number
Single-Stage Pump
Working Pressure
13bar/16bar
Influent Type of Impeller
Single Suction Pump
Position of Pump Shaft
Vertical Pump
Pump Casing Combined
Verticaljoint Surface Pump
Mounting Height
Since Irrigation Centrifugal Pumps
Impeller
Closed
Usage
Cycle
Temperature Range of Fluid
-20 ° C to+140 ° C
Nominal Diameter
DN 40 to DN 200
Protection Grade
IP55
Temperature Range During Operation
0 ° C to+40 ° C
Temperature Range During Storage
-20 ° C to+60 ° C
Transport Package
Wooden Chest
Specification
Dimensions comply with DIN EN 733 standard
Trademark
Wilo
Origin
Germany
Production Capacity
23

Product Description

The Wilo Stratos GIGA high-efficiency pipeline pump with IE5 motor and electronic power regulation device adopts a dry rotor pump structure. Single stage low-pressure centrifugal pump with flange connection and mechanical seal.

  Product Description                                                          
Wilo Stratos GIGA is a single-stage low-pressure pump suitable for heating, air conditioning, and refrigeration systems, especially for buildings with high water delivery head and volumetric flow rate.
Flow range  : <450m³/h
Lift range : ≤80m
Max.operating pressure at different fluid temperature : 13bar/16bar
Temperature range : -20ºC~+140ºC
Aplication field :The Stratos GIGA series is mainly used for supplying heating water (according to VDI 2035 standard), cold water, and water ethylene glycol mixtures, and does not contain abrasive substances in heating systems, cold water systems, and cooling systems.
Wilo-Stratos Giga Vertical Single-Stage Low-Pressure High Flow Heating Circulation Pump
 Summary                                                                   

Wilo Stratos GIGA is an ideal high-efficiency pump for heating, air conditioning, and refrigeration systems, achieving maximum power with the highest energy efficiency.

Your advantages                                                         
  
  • Innovative high-efficiency pump for maximum overall efficiency levels
  • High-efficiency motor with efficiency class IE5 according to IEC 60034-30-2
  • Optional interfaces for connection to building automation using insertable IF modules

Wilo-Stratos Giga Vertical Single-Stage Low-Pressure High Flow Heating Circulation Pump
Design                                                        

High-efficiency in-line pump with IE5 motor and electronic power adjustment in glanded pump design. Version as single-stage low-pressure centrifugal pump with flange connection and mechanical seal.

Application                                                  

The pumping of heating water (in accordance with VDI 2035), chilled water and water-glycol mixtures without abrasive substances in heating, chilled water and cooling systems.

Equipment/function

Operating modes                                                                
  • Δp-c for constant differential pressure
  • Δp-v for variable differential pressure
  • PID-Control
  • Constant speed (n=constant)
Manual operation level                                                       
  • Green button and display
Manual functions                                                                
  • Differential pressure setpoint setting
  • Setting the speed (manual control mode)
  • Setting the operating mode
  • Setting the pump ON/OFF
  • Configuration of all operating parameters
  • Fault acknowledgement
External control functions                                                  
  • "Overriding Off" control input
  • "External pump cycling" control input (effective only in dual-pump operation)
  • Analogue input 0 - 10 V, 0 - 20 mA for constant speed (DDC) and remote setpoint adjustment
  • Analogue input 2 - 10 V, 4 - 20 mA for constant speed (DDC) and remote setpoint adjustment
  • Analogue input 0 - 10 V for actual value signal from pressure sensor
  • Analogue input 2 - 10 V, 0 - 20 mA, 4 - 20 mA for actual value signal from pressure sensor
Signal and display functions                                          
  • Collective fault signal SSM
  • Collective run signal SBM
Data exchange                                                                 
  • Infrared interface for wireless data exchange with IR-Stick
  • Plug-in position for Wilo IF-Modules (Modbus, BACnet, CAN, PLR, LON) for connection to building automation
Safety functions                                                              
  • Full motor protection with integrated trip electronics
  • Access disable
Dual-pump management(2 x single pumps)                 
  • Main/standby operation (automatic fault-actuated switchover)
  • Pump cycling main/standby operation after 24 hours
  • Parallel operation
  • Parallel operation (efficiency-optimised peak-load activation and deactivation)
Typekey                                                    
 

Example

Wilo-Stratos GIGA 40/1-51/4,5

Stratos

High-efficiency pump

GIGA

In-line single pump

40

Nominal flange diameter DN

1-51

Nominal delivery head range in [m]

4.5

Orientation value of the rated power P2 in kW

-R1

Version without differential pressure sensor

   
 Technical data                                                        
  • Permitted temperature range of the fluid: -20 °C to +140 °C
  • Mechanical seal for pumping water up to Tmax = +140 °C. Up to T ≤ +40 °C, a glycol admixture of 20 % to 40 % by volume is permissible. An alternative mechanical seal must be provided for water-glycol mixtures with a glycol content of > 40% to max. 50% by volume and a fluid temperature of > +40 °C to max. +120 °C or other fluids that differ from water. When using water-glycol mixtures, the use of an S1 variant with a corresponding mechanical seal is generally recommended.
  • Mains connection:
  • 3~440 V ±10 %, 50/60 Hz
  • 3~400 V ±10 %, 50/60 Hz
  • 3~380 V -5% +10%, 50/60 Hz

Compliance with electromagnetic compatibility without additional measures:

    • Interference emission for residential environment according to EN 61800-3:2018
    • Interference immunity for industrial environments according to EN 61800-3:2018
  • Protection class IP55
  • Nominal diameter DN 40 to DN 200
  • Max. operating pressure 16 bar up to +120 °C, 13 bar up to +140 °C
Materials                                                   
  • Pump housing and lantern: EN-GJL-250
  • Impeller: PPS-GF40 or EN-GJL-200 depending on the type
    • Special version: Bronze CuSn 10 (depending on type)
    • Special version: Stainless steel 1.4408 (depending on type)
  • Shaft: 1.4122 or 1.4542 depending on type
  • Mechanical seal: AQEGG; other mechanical seals on request
Scope of delivery                                       
  • Pump
  • Installation and operating instructions
Options                                                    
  • …-L1 variant with bronze impeller (at additional charge)
  • …-L4 variant with stainless steel impeller (at additional charge)
  • Variant …-R1 without differential pressure sensor
  • …-S1 variant with special mechanical seal
Wilo-Stratos Giga Vertical Single-Stage Low-Pressure High Flow Heating Circulation PumpWilo-Stratos Giga Vertical Single-Stage Low-Pressure High Flow Heating Circulation PumpWilo-Stratos Giga Vertical Single-Stage Low-Pressure High Flow Heating Circulation Pump

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier