Wq/CE Type Cuitting Submersiblesewage Pump Especially Suitable for Pumping Sewage and Waste Sites Containing Long Fiber Material

Product Details
Customization: Available
Type: Submersible Sewage Pump
Method: Sewage Treatment
Gold Member Since 2025

Suppliers with verified business licenses

Registered Capital
10000000 RMB
Plant Area
1001~2000 square meters
  • Wq/CE Type Cuitting Submersiblesewage Pump Especially Suitable for Pumping Sewage and Waste Sites Containing Long Fiber Material
  • Wq/CE Type Cuitting Submersiblesewage Pump Especially Suitable for Pumping Sewage and Waste Sites Containing Long Fiber Material
  • Wq/CE Type Cuitting Submersiblesewage Pump Especially Suitable for Pumping Sewage and Waste Sites Containing Long Fiber Material
  • Wq/CE Type Cuitting Submersiblesewage Pump Especially Suitable for Pumping Sewage and Waste Sites Containing Long Fiber Material
  • Wq/CE Type Cuitting Submersiblesewage Pump Especially Suitable for Pumping Sewage and Waste Sites Containing Long Fiber Material
  • Wq/CE Type Cuitting Submersiblesewage Pump Especially Suitable for Pumping Sewage and Waste Sites Containing Long Fiber Material
Find Similar Products

Basic Info.

Model NO.
WQ-CE
Usage
Drainage
Capacity
6~500m³/H
Head
5~45m;
Medium Temperature
T≤40ºC
Medium Consistency
≤1.1X10³kg/M′
Medium Phscope
5~9
Motorinsulation Class
F/ Ipx8
Transport Package
Standard Export Plywood Case or Carton
Specification
electro-coating
Trademark
EAST
Production Capacity
100

Product Description

Product Scope                  
Apply to discharges of sewage, municipal engineering, hospitals, buidinas, hotels,restaurants and other industriesespecially suitable for pumping sewage and waste sites containing long fiber material.

Product Features               
The overall head of the diving with a cast cable seal design; special processing technology cable ends, even if thatdoes not damage the cable jacket water infiltrated the motor, oi-resistant rubber flexible cables meet the nationalstandard GB /T 5013.4 and JB /T8735.2; But the end of the cable can not contact with water, waterinto the cablewill seriously reduce the insulation resistance of the cable, affecting the safety of the motor;Mofor F class insulation, enclosure profection class lPx8, power < pumps, motors built 105 'c thermal protector 1 lkwto ensure that the pump motor is running against overheating, prevent equipment burned;an plastic baas, folet paper, sanitary napkins, cotton, and other similar oblects chopped and carage smoothly, oncstrips of cloth nor wilit cause any wound pump pars, pumps and piping to be able fo avoid sewage The clogged;The impeller and the cutting plate with corrosion resistant materials and specially treated to ensure that the cuttinowheel and the cuting edge of the disc has a suficient strength and stiffness, resistance to both corrosion and wearresistance.long-term stay sharp:Impellers, pump hydraulic design, size and pump impeller flow channel dimensions match road jingdang, excellenperformance, stable, mature, through a strong ability to make shredded debris can pass:The head coaxial with the motor, using a minor axis extending structural desian, the cantilever shaft is short, highstrenath and stifness of the shaft, the shaft of the ow vibration operation,the mechanicalseal so that eakage iarge reductionin the mechanical seal and the bearing has a long lifeset between the impeler and cuttina plate scrapinas slot, which can effectively be saueezed into a thin plate betweerthe impeller and the cutting and scraping debris toughness to avoid pump super power and stall;The uniaue structural desian, can auickly and easily adiust the clearance between the impeler and the cutting disoto make efficient pump performance is always maintained at the state and do not need to be adiusted when thepumpisremoved without special tools;If the user has previously used the ordinary type wQ submersible sewage pump coupling installation company, wanto cut into the same tvpe of submersible sewage pump discharge diameter, then simply change the pump withouithe need to change the coupling device,save yourexpenses;

Wq/CE Type Cuitting Submersiblesewage Pump Especially Suitable for Pumping Sewage and Waste Sites Containing Long Fiber Material
Operating Scope                  
Capacity:6~500m³/h
Head:5~45m
Medium temperature:T≤40ºC
.PH Medium PHscope:5~9;
Motorinsulation class:FGrade
Motorinsulation class:IPX8
Medium consistency:≤1.1x10³kg/m³
Wq/CE Type Cuitting Submersiblesewage Pump Especially Suitable for Pumping Sewage and Waste Sites Containing Long Fiber MaterialWq/CE Type Cuitting Submersiblesewage Pump Especially Suitable for Pumping Sewage and Waste Sites Containing Long Fiber MaterialWq/CE Type Cuitting Submersiblesewage Pump Especially Suitable for Pumping Sewage and Waste Sites Containing Long Fiber MaterialWq/CE Type Cuitting Submersiblesewage Pump Especially Suitable for Pumping Sewage and Waste Sites Containing Long Fiber Material
Production Plant                      
Wq/CE Type Cuitting Submersiblesewage Pump Especially Suitable for Pumping Sewage and Waste Sites Containing Long Fiber MaterialWq/CE Type Cuitting Submersiblesewage Pump Especially Suitable for Pumping Sewage and Waste Sites Containing Long Fiber MaterialWq/CE Type Cuitting Submersiblesewage Pump Especially Suitable for Pumping Sewage and Waste Sites Containing Long Fiber MaterialWq/CE Type Cuitting Submersiblesewage Pump Especially Suitable for Pumping Sewage and Waste Sites Containing Long Fiber MaterialWq/CE Type Cuitting Submersiblesewage Pump Especially Suitable for Pumping Sewage and Waste Sites Containing Long Fiber MaterialWq/CE Type Cuitting Submersiblesewage Pump Especially Suitable for Pumping Sewage and Waste Sites Containing Long Fiber Material
Wq/CE Type Cuitting Submersiblesewage Pump Especially Suitable for Pumping Sewage and Waste Sites Containing Long Fiber Material
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier