Wilo Cronoline Il E Single Stage Series Structure CNC Circulating Pump for Heating and Irrigation

Product Details
Customization: Available
Max.Head: 80m
Max.Capacity: 550m³/H
Gold Member Since 2025

Suppliers with verified business licenses

Registered Capital
10000000 RMB
Plant Area
1001~2000 square meters
  • Wilo Cronoline Il E Single Stage Series Structure CNC Circulating Pump for Heating and Irrigation
  • Wilo Cronoline Il E Single Stage Series Structure CNC Circulating Pump for Heating and Irrigation
  • Wilo Cronoline Il E Single Stage Series Structure CNC Circulating Pump for Heating and Irrigation
  • Wilo Cronoline Il E Single Stage Series Structure CNC Circulating Pump for Heating and Irrigation
  • Wilo Cronoline Il E Single Stage Series Structure CNC Circulating Pump for Heating and Irrigation
  • Wilo Cronoline Il E Single Stage Series Structure CNC Circulating Pump for Heating and Irrigation
Find Similar Products

Basic Info.

Model NO.
Wilo-CronoLine-IL-E
Driving Type
CNC
Impeller Number
Single-Stage Pump
Working Pressure
13bar/16bar
Influent Type of Impeller
Single Suction Pump
Position of Pump Shaft
Vertical Pump
Pump Casing Combined
Verticaljoint Surface Pump
Mounting Height
Since Irrigation Centrifugal Pumps
Impeller
Closed
Usage
Pump, Hot Water Heating System, Cooling Water and Cold W
Temperature Range During Storage
-20 °c to +60 °c
Temperature Range During Operation
0 °c to +40 °c
Fluid Temperature
-20 °c to +140 °c
Insulation Level
F
Protection Grade
IP55
Transport Package
Wooden Chest
Specification
Series structure
Trademark
Wilo
Origin
Germany
Production Capacity
19

Product Description

Wilo-CronoLine-IL-E is a series structure CNC dry rotor single head pump with flange connection and automatic power regulation.
Product Description                                                               

  
Wilo-CronoLine-IL-E adopts an integrated electronic power regulation device, which can save energy and is a professional device that complies with the EN 61000-3-2 standard.
Flow range  : <550m³/h
Lift range : ≤80m
Max.operating pressure at different fluid temperature : 13bar/16bar
Temperature range : -20ºC~+140ºC
Nominal diameter :DN 40 to DN 200

Aplication field :The CronoLine-IL-E series is mainly suitable for hot water heating systems, cooling water and cold water circulation circuits, industrial circulation systems, heat transfer circulation circuits, and irrigation systems
Wilo Cronoline Il E Single Stage Series Structure CNC Circulating Pump for Heating and Irrigation
 Your advantages                                                              
  • Energy savings due to integrated electronic power adjustment
  • Optional interfaces for bus communication using plug-in IF-Modules
  • Simple operation with Green Button Technology and display
  • Integrated dual pump management
  • Integrated full motor protection (PTC thermistor sensor) with trip electronics
Wilo Cronoline Il E Single Stage Series Structure CNC Circulating Pump for Heating and Irrigation

Equipment/function

Operating modes                                                                    
  • Δp-c for constant differential pressure
  • Δp-v for variable differential pressure
  • PID-Control
  • Constant speed (n=constant)
Manual operation level                                                          
  • Green button and display
  • Differential pressure setpoint setting
  • Setting the speed (manual control mode)
  • Setting the operating mode
  • Setting the pump ON/OFF
  • Configuration of all operating parameters
  • Fault acknowledgement
External control functions                                                    
  • "Overriding Off" control input
  • "External pump cycling" control input (only effective in twin-head pump operation)
  • Analogue input 0 - 10 V, 0 - 20 mA for constant speed (DDC) and remote setpoint adjustment
  • Analogue input 2 - 10 V, 4 - 20 mA for constant speed (DDC) and remote setpoint adjustment
  • Analogue input 0 - 10 V for actual value signal from pressure sensor
  • Analogue input 2 - 10 V, 0 - 20 mA, 4 - 20 mA for actual value signal from pressure sensor
Signal and display functions                                                 
  • Collective fault signal SSM
  • Collective run signal SBM
Data exchange                                                                        
  • Infrared interface for wireless data exchange with IR-Stick
  • Plug-in position for Wilo IF-Modules (Modbus, BACnet, CAN, PLR, LON) for connection to building automation
Safety functions                                                                     
  • Full motor protection with integrated trip electronics
  • Access disable
Dual pump management (twin-head pump or 2 x single pumps)  
  • Main/standby operation (automatic fault-actuated switchover)
  • Pump cycling main/standby operation after 24 hours
  • Parallel operation
  • Parallel operation (efficiency-optimised peak-load activation and deactivation)
Typekey                                                                       
 

Example

IL-E 50/190-11/2-R1

IL-E

In-line pump with electronic control

50

Nominal diameter DN of the pipe connection

190

Nominal impeller diameter

11

Rated power P2 in kW

2

Number of poles

R1

Version without pressure sensor

   

 Technical data                                                                                  
  • Permissible temperature range of -20 °C to +140 °C
  • Mechanical seal for pumping water up to Tmax = +140 °C. Up to T ≤ +40 °C, a glycol admixture of 20 % to 40 % by volume is permissible. An alternative mechanical seal must be provided for water-glycol mixtures with a glycol content of > 40% to max. 50% by volume and a fluid temperature of > +40 °C to max. +120 °C or other fluids that differ from water. When using water-glycol mixtures, the use of an S1 variant with a corresponding mechanical seal is generally recommended.
  • Mains connection
    • 3~440 V ±10 %, 50/60 Hz
    • 3~400 V ±10%, 50/60 Hz
    • 3~380 V -5% +10%, 50/60 Hz
  • Compliance with electromagnetic compatibility without additional measures:
    • Interference emission for residential environment according to EN 61800-3:2018
    • Interference immunity for industrial environments according to EN 61800-3:2018
  • Protection class IP55
  • Nominal diameter DN 40 to DN 200
  • Max. operating pressure 16 bar up to +120 °C, 13 bar up to +140 °C
Materials                                                                     
  • Pump housing and lantern: EN-GJL-250
  • Impeller
    • Standard version: EN-GJL-200
    • Special version: Bronze CuSn 10
    • Special version: Stainless steel 1.4408
  • Shaft: 1.4122
  • Mechanical seal: AQEGG; other mechanical seals on request

Construction                                                                     

Single-stage, low-pressure centrifugal pump in in-line design with

  • Mechanical seal
  • Flange connection
  • Lantern
  • Coupling
  • Drive with integrated electronic speed control
Wilo Cronoline Il E Single Stage Series Structure CNC Circulating Pump for Heating and IrrigationWilo Cronoline Il E Single Stage Series Structure CNC Circulating Pump for Heating and IrrigationWilo Cronoline Il E Single Stage Series Structure CNC Circulating Pump for Heating and Irrigation

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier